Product Code:
|
37425-37 |
|
Product Name:
|
ADAMS ROOM FOGGER |
|
Manufacturer Information
|
|
|
Company Name:
|
Distributed by: |
|
|
Farnam Companies, Inc. |
|
|
301 West Osborn Road |
|
|
Phoenix, AZ |
|
Emergency Contact:
|
CHEMTREC (800)424-9300 |
|
Alternate Emergency Contact:
|
District of Columbia (202)483-0414 |
|
Information:
|
Farnam Companies, Inc. (800)234-2269 |
|
Chemical Family:
|
Water-based aerosol |
|
Additional Identity Information
|
|
7013 |
| Hazardous Components (Chemical Name) |
CAS # |
Concentration |
OSHA PEL |
ACGIH TLV |
| Pyrethrins |
121-29-9 |
0.05 % |
No data. |
No data. |
| N-OCTYL BICYCLOHEPTENE DICARBOXIMIDE |
113-48-4 |
0.4 % |
No data. |
No data. |
| Permethrin |
52645-53-1 |
0.4 % |
No data. |
No data. |
| Pyriproxyfen (NYLAR/BIOLAR) |
95737-68-1 |
0.1 % |
No data. |
No data. |
|
Emergency Overview
|
|
No data available. |
|
Route(s) of Entry:
|
Inhalation? Yes , Skin? Yes , Eyes? Yes , Ingestion? Yes |
|
Potential Health Effects (Acute and Chronic)
|
|
No data available. |
|
LD 50 / LC 50
|
Acute Oral LC(50) > 5 g/kg (rats)
|
|
Signs and Symptoms Of Exposure
|
EYES: Force of released product may damage the
eyes. SKIN: Prolonged or repeated exposure
may cause irritation and reddening of the skin. INHALATION: Excessive inhalation can cause nasal
and respiratory irritation, headaches and nervous
system depression (fatigue, dizziness, loss of
coordination). INGESTION: Can cause stomach
irritation, resulting in nausea, cramps and
vomiting. Can also cause nervous system
depression (fatigue, dizziness, loss of
coordination).
|
|
Emergency and First Aid Procedures
|
EYES: Immediately flush with large amounts of
water for at least 15 minutes. If irritation
persists, get medical attention. SKIN:
Immediately flush affected areas with water.
Remove contaminated clothing and wash affected
areas with soap and water. If irritation
persists, get medical attention. INHALATION:
Remove affected person to fresh air. Give oxygen,
if necessary. If breathing has stopped,
administer artificial respiration and get medical
attention immediately. INGESTION: Do NOT
induce vomiting. Keep affected person warm and
quiet and get medical attention immediately. |
|
Flash Pt:
|
172.00 F Method Used: TAG Closed Cup |
|
Explosive Limits:
|
LEL: No data. UEL: No data. |
|
Fire Fighting Instructions
|
|
Treat as an oil fire. Use a full-faced self-contained breathing apparatus along with full protective gear. Keep nearby containers and equipment cool with a water spray. Contain the run-off, if possible, for proper disposal |
|
Flammable Properties and Hazards
|
|
Heating the aerosol container may build up pressure, causing it to burst. |
|
Extinguishing Media
|
|
Foam, carbon dioxide, or dry chemical. |
|
Unsuitable Extinguishing Media
|
|
No data available. |
|
Steps To Be Taken In Case Material Is Released Or Spilled
|
|
Eliminate all ignition sources. Contain the spill. Soak up the spill with an appropriate absorbent and transfer into waste container for proper disposal. Clean the spill area with detergent and water. |
|
Precautions To Be Taken in Handling
|
|
Store containers upright and closed. Store in
areas that are cool, dry and well-ventilated.
Store away from heat, ignition sources and strong
oxidizers. Do not contaminate water, feed or food
by storage, handling, application or disposal. Do
not puncture or incinerate container. Do not
direct spray towards face. Read and follow all
precautions and instructions on the product label. |
|
Respiratory Equipment (Specify Type)
|
|
None necessary, if used properly. |
|
Eye Protection
|
|
Not necessary, if used properly. |
|
Protective Gloves
|
|
No data available. |
|
Other Protective Clothing
|
|
Avoid contact with skin and clothing. |
|
Engineering Controls (Ventilation etc.)
|
|
Mechanical ventilation may be useful when using this product in enclosed spaces. |
|
Additional Exposure Control Information
|
Acute Oral LD(50) > 5 g/kg (rats) Acute Dermal LD(50) > 2 g/kg (rabbits) Acute Inhalation LC(50) > 5.12 mg/L-air |
|
Physical States:
|
[ ] Gas [ X ] Liquid [ ] Solid |
|
Melting Point:
|
No data. |
|
Boiling Point:
|
No data. |
|
Autoignition Pt:
|
No data. |
|
Flash Pt:
|
172.00 F Method Used: TAG Closed Cup |
|
Explosive Limits:
|
LEL: No data. UEL: No data. |
|
Specific Gravity (Water = 1):
|
0.968 at 20.0 C |
|
Bulk density:
|
No data. |
|
Vapor Pressure (vs. Air or mm Hg):
|
No data. |
|
Vapor Density (vs. Air = 1):
|
No data. |
|
Evaporation Rate (vs Butyl Acetate=1):
|
No data. |
|
Solubility in Water:
|
No data. |
|
Solubility Notes
|
Non-volatiles are an emulsion
|
|
Percent Volatile:
|
N.A. |
|
Heat Value:
|
No data. |
|
Particle Size:
|
No data. |
|
Corrosion Rate:
|
No data. |
|
pH:
|
No data. |
|
Appearance and Odor
|
|
Non-volatiles are a pale yellow-colored liquid. Odor of petroleum solvent |
|
Additional Physical Information
|
Liquified petroleum gas TLV-1000 ppm (ACGIH) Refined petroleum solvent TLV-350 mg/cu m (NIOSH) |
|
Stability:
|
Unstable [ ] Stable [ X ] |
|
Conditions To Avoid - Instability
|
|
Avoid heat and open flames. Do not puncture container. |
|
Incompatibility - Materials To Avoid
|
|
No data available. |
|
Hazardous Decomposition Or Byproducts
|
|
No data available. |
|
Hazardous Polymerization:
|
Will occur [ ] Will not occur [ X ] |
|
Conditions To Avoid - Hazardous Polymerization
|
|
No data available. |
|
No data available. |
|
Carcinogenicity/Other Information
|
|
No data available. |
| Hazardous Components (Chemical Name) |
CAS # |
NTP |
IARC |
ACGIH |
OSHA |
| Pyrethrins |
121-29-9 |
n.a. |
n.a. |
n.a. |
n.a. |
| N-OCTYL BICYCLOHEPTENE DICARBOXIMIDE |
113-48-4 |
n.a. |
n.a. |
n.a. |
n.a. |
| Permethrin |
52645-53-1 |
n.a. |
n.a. |
n.a. |
n.a. |
| Pyriproxyfen (NYLAR/BIOLAR) |
95737-68-1 |
n.a. |
n.a. |
n.a. |
n.a. |
|
Carcinogenicity:
|
NTP? No IARC Monographs? No OSHA Regulated? No |
|
Waste Disposal Method
|
|
Contaminated absorbent and wash water should be disposed of according to local, state and federal regulations. |
|
RCRA/CERCLA HAZARDOUS WASTE: CERCLA RQ-value for pyrethrings is 1 lb. |
|
Company Policy or Disclaimer
|
|
The information and data herein are believed to be accurate and have been compiled from sources believed to be reliable. It is offered for your consideration, investigation and verification. |