Return to MSDS List , Previous MSDS , Next MSDS

M A T E R I A L   S A F E T Y   D A T A   S H E E T

Generated  12/30/2009,   Revision  01/22/2009,   Supercedes Revision  04/26/2007,   Date Created  09/25/2003

SECTION 1. Product and Company Identification
ADAMS DUAL ACTION FLEA & TICK COLLAR

Product Code: 2517-61-37425
Product Name: ADAMS DUAL ACTION FLEA & TICK COLLAR
Manufacturer Information
     Company Name: Distributed by:
  Farnam Companies, Inc.
  301 West Osborn Road
  Phoenix, AZ
     Emergency Contact: CHEMTREC                                (800)424-9300
     Alternate Emergency Contact: District of Columbia                    (202)483-0414
     Information: Farnam Companies, Inc.                  (800)234-2269
Additional Identity Information
Large Dogs - 6661, 3001223
Medium Dogs - 6660, 3001222
Cats - 6662

SECTION 2. Composition/Information on Ingredients
ADAMS DUAL ACTION FLEA & TICK COLLAR

Hazardous Components (Chemical Name) CAS # Concentration OSHA PEL ACGIH TLV
N-OCTYL BICYCLOHEPTENE DICARBOXIMIDE 113-48-4 3.0 % No data. No data.
Phenothrin 26002-80-2 3.0 % No data. No data.
Propoxur 114-26-1 9.0 % No data. No data.

SECTION 3. Hazards Identification
ADAMS DUAL ACTION FLEA & TICK COLLAR

Emergency Overview
No data available.
Route(s) of Entry: Inhalation? Yes , Skin? Yes , Eyes? Yes , Ingestion? No
Potential Health Effects (Acute and Chronic)
No data available.
Signs and Symptoms Of Exposure
May cause cholinesterase inhibition. May cause blurred vision, profuse sweating. cramps, nausea, vomiting, twitching, tremors, or convulsion. Long term exposure may cause weakness and anorexia resembling influenza.

SECTION 4. First Aid Measures
ADAMS DUAL ACTION FLEA & TICK COLLAR

Emergency and First Aid Procedures
If swallowed, do NOT induce vomiting. Give victim a glass of water or milk. Call a physician or poison control center immediately. Never give anything by mouth to an unconscious person.
Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get immediate medical attention.
IF IN EYES: Flush immediately with water. Hold eyelids apart and flush eyes with plenty of water. After initial flushings, remove any contact lenses and continue flushing for at least 15 minutes. Have eyes examined and tested by medical personnel.
IF ON SKIN: Remove contaminated clothing and launder before reuse. Wash skin with soap and water. Get medical attention.
Note to Physician
Dust released by this collar is a cholinesterase inhibitor. Atropine is antidotal and preferabley given I.V. to effect if toxic signs are present.

SECTION 5. Fire Fighting Measures
ADAMS DUAL ACTION FLEA & TICK COLLAR

Flash Pt: No data.
Explosive Limits: LEL:  No data.                                    UEL:  No data.
Fire Fighting Instructions
As in any fire involving chemicals, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH approved or equivalent and full protective gear.
Flammable Properties and Hazards
No data available.
Hazardous Combustion Products
In fire conditions, CO, CO2, and NOx, POx, and SOx may be produced.
Extinguishing Media
As appropriate for surrounding materials
Unsuitable Extinguishing Media
No data available.

SECTION 6. Accidental Release Measures
ADAMS DUAL ACTION FLEA & TICK COLLAR

Steps To Be Taken In Case Material Is Released Or Spilled
Salvage if not contaminated. Sweep and/or scoop up spill, dispose of any unusable material as approved by federal, state and local regulations.

SECTION 7. Handling and Storage
ADAMS DUAL ACTION FLEA & TICK COLLAR

Precautions To Be Taken in Handling
Use only in a well ventilated area.

SECTION 8. Exposure Controls/Personal Protection
ADAMS DUAL ACTION FLEA & TICK COLLAR

Respiratory Equipment (Specify Type)
None needed under conditions of normal use.
Eye Protection
Eye wash station in work area
Protective Gloves
No data available.
Engineering Controls (Ventilation etc.)
No data available.
Work/Hygienic/Maintenance Practices
Contaminated clothing and shoes should be cleaned before reuse. Eye wash stations should be available. Wash hands after use and before eating, smoking, or using restroom.

SECTION 9. Physical and Chemical Properties
ADAMS DUAL ACTION FLEA & TICK COLLAR

Physical States: [   ] Gas       [   ] Liquid       [ X ] Solid
Melting Point: No data.
Boiling Point: No data.
Autoignition Pt: No data.
Flash Pt: No data.
Explosive Limits: LEL:  No data.                                    UEL:  No data.
Specific Gravity (Water = 1): 1.15
Bulk density: No data.
Vapor Pressure (vs. Air or mm Hg): No data.
Vapor Density (vs. Air = 1): No data.
Evaporation Rate (vs Butyl Acetate=1): No data.
Solubility in Water: No data.
Percent Volatile: N.A.
Heat Value: No data.
Particle Size: No data.
Corrosion Rate: No data.
pH: No data.
Appearance and Odor
PVC strip with baby powder odor.

SECTION 10. Stability and Reactivity
ADAMS DUAL ACTION FLEA & TICK COLLAR

Stability: Unstable [    ]       Stable [ X ]
Conditions To Avoid - Instability
No data available.
Incompatibility - Materials To Avoid
No data available.
Hazardous Decomposition Or Byproducts
No data available.
Hazardous Polymerization: Will occur [    ]       Will not occur [ X ]
Conditions To Avoid - Hazardous Polymerization
No data available.

SECTION 11. Toxicological Information
ADAMS DUAL ACTION FLEA & TICK COLLAR

No data available.
Carcinogenicity/Other Information
No data available.
Hazardous Components (Chemical Name) CAS # NTP IARC ACGIH OSHA
N-OCTYL BICYCLOHEPTENE DICARBOXIMIDE 113-48-4 n.a. n.a. n.a. n.a.
Phenothrin 26002-80-2 n.a. n.a. n.a. n.a.
Propoxur 114-26-1 n.a. n.a. A3 n.a.
Carcinogenicity: NTP? No       IARC Monographs? No       OSHA Regulated? No

SECTION 12. Ecological Information
ADAMS DUAL ACTION FLEA & TICK COLLAR

No data available.

SECTION 13. Disposal Considerations
ADAMS DUAL ACTION FLEA & TICK COLLAR

Waste Disposal Method
No data available.

SECTION 14. Transport Information
ADAMS DUAL ACTION FLEA & TICK COLLAR

LAND TRANSPORT (US DOT)
     DOT Proper Shipping Name No data available.

SECTION 15. Regulatory Information
ADAMS DUAL ACTION FLEA & TICK COLLAR

No data available.

SECTION 16. Other Information
ADAMS DUAL ACTION FLEA & TICK COLLAR

No data available.