Return to MSDS List , Previous MSDS , Next MSDS

M A T E R I A L   S A F E T Y   D A T A   S H E E T


SECTION 1. Product and Company Identification
TISSUMEND II SC

Product Code: VPL-TISSUMNDSC
Product Name: TISSUMEND II SC
Manufacturer Name and Address:Telephone Numbers:Dates:
Distributed by:CHEMTREC(800)424-9300Date Created: 01/11/2007
Veterinary Products LaboratoriesRevision: 07/26/2007
P.O. Box 34820Information:(888)241-9545Printed: 07/26/2007
Phoenix, AZ. 85067-4820
Responsible Person: SFaith/Regulatory , Phone #:
Additional Identity Information
3006178 1.5 ml

SECTION 2. Composition/Information on Ingredients
TISSUMEND II SC

  Hazardous Components (Chemical Name)  CAS #   Concentration
1. Methoxypropyl cyanoacrylate ethyl cyanoacrylate NA > 1.0 %
2. Butylated hydroxyanisole (BHA) 25013-16-5 0.05 %
   OSHA PEL ACGIH TLV ACGIH STEL
1.   No data.   2 ppm   4 ppm  
2.   No data.   No data.   No data.  

SECTION 3. Hazards Identification
TISSUMEND II SC

Emergency Overview
EYES: Adhesive solidifies immediately on contact and bonds eyelids.
SKIN: On contact, immediate bonding of mouth and skin will occur. Frequent or prolonged contact may irritate skin.
INHALATION: Vapors may be irritating to mucous membranes and respiratory system.
INGESTION: Immediate bonding of mouth will occur. Seek medical attention.

Route(s) of Entry: Inhalation? Yes , Skin? Yes , Eyes? Yes , Ingestion? Yes
Potential Health Effects (Acute and Chronic)
Not a carcinogen; no chronic effects are known.
Carcinogenicity: NTP? N.A. , IARC Monographs? N.A. , OSHA Regulated? N.A.
Carcinogenicity/Other Information
No data available.
Signs and Symptoms Of Exposure
No data available.
Medical Conditions Generally Aggravated By Exposure
None known.

SECTION 4. First Aid Measures
TISSUMEND II SC

Emergency and First Aid Procedures
EYES: In case of contact with eyes, flush with large amounts of water. Seek medical attention. Cured adhesive will not bond well to surface of eye, but corneal damage from abrasion may result. Do not wear contact lenses when working with this material.
SKIN: In case of skin contact, and if polymerization has occurred, do not attempt to remove. Wash with large amounts of soap and water while flexing bonded skin parts. This procedure will slowly release bonded areas. DO NOT mechanically remove cured adhesive or attempt to pull skin apart.
INHALATION: Remove to fresh air. Call a physician if breathing is difficult.
INGESTION: Possible tissue bonding of mouth may occur. Seek medical attention.
Note to Physician
No data available.

SECTION 5. Fire Fighting Measures
TISSUMEND II SC

Flash Pt: > 200.00 F Method Used: No data.
Explosive Limits: LEL: No data. UEL: No data.
Extinguishing Media
Carbon dioxide, dry chemical, foam
Fire Fighting Instructions
Wear self-contained breathing apparatus to protect against potentially toxic and irritating fumes.
Flammable Properties and Hazards
Emits toxic fumes under combustion. Will polymerize upon contact with water.
Hazardous Combustion Products
No data available.

SECTION 6. Accidental Release Measures
TISSUMEND II SC

Steps To Be Taken In Case Material Is Released Or Spilled
SMALL SPILLS: Wipe up with cloth. Immediately soak cloth with water to polymerize the adhesive. CAUTION! Cloth containing adhesive may undergo autoignition if not soaked in water.
LARGE SPILLS: Flood area with water. When cured, remove film with a scraper. Wear protective clothing.

SECTION 7. Handling and Storage
TISSUMEND II SC

Precautions To Be Taken in Handling
Avoid contact with eyes, skin and clothing.

Precautions To Be Taken in Storing
Store in a cool, dry area. Avoid exposure to humid air. Avoid temperatures above 80 degrees F.
Other Precautions
No data available.

SECTION 8. Exposure Controls/Personal Protection
TISSUMEND II SC

Respiratory Equipment (Specify Type)
No data available.
Eye Protection
Safety goggles, chemical goggles or face shield.
Protective Gloves
Rubber
Other Protective Clothing
No special clothing required for low volume activity.
Engineering Controls (Ventilation etc.)
Local exhaust recommended.

SECTION 9. Physical and Chemical Properties
TISSUMEND II SC

Solubility Notes
Will polymerize upon exposure to water.
Physical States:  [ ] Gas , [ X ] Liquid , [ ] Solid
Boiling Point: No data.
Melting Point:  No data.
Specific Gravity (Water = 1): No data.
Density: No data.
Vapor Pressure (vs. Air or mm Hg): No data.
Vapor Density (vs. Air = 1): No data.
Evaporation Rate (vs Butyl Acetate=1):  No data.
Solubility in Water: No data.
Percent Volatile: No data.
Saturated Vapor Concentration: No data.
Viscosity: No data.
pH: No data.
Appearance and Odor
Clear or violet slightly viscous liquid.

SECTION 10. Stability and Reactivity
TISSUMEND II SC

Stability: Unstable [ ] Stable [ X ]
Conditions To Avoid - Instability
Heat and humidity.
Incompatibility - Materials To Avoid
Hazardous polymerization on exposure to water, alkaline materials, peroxides.
Hazardous Decomposition Or Byproducts
Emits toxic fumes upon combustion.
Hazardous Polymerization: Will occur [ ] Will not occur [ X ]
Conditions To Avoid - Hazardous Polymerization
Will polymerize on contact with skin and eyes and could bond with other surfaces. No hazardous release of energy will occur.
Additional Stability/Reactivity Information
NFPA Hazard Class 2 = Moderate

SECTION 11. Toxicological Information
TISSUMEND II SC

None known
Chronic Toxicological Effects
Not a carcinogen.

SECTION 12. Ecological Information
TISSUMEND II SC

None known

SECTION 13. Disposal Considerations
TISSUMEND II SC

Waste Disposal Method
Dispose of according to all local, State, and Federal regulations.

SECTION 14. Transport Information
TISSUMEND II SC

DOT Proper Shipping Name
No data available.

Additional Transport Information
No data available.

SECTION 15. Regulatory Information
TISSUMEND II SC

No data available.

SECTION 16. Other Information
TISSUMEND II SC

Supercedes Revision 01/11/2007
Each "sterilization aid" pouch contains 225 mg of the celcon plastic flake - small, white celcon pouch to be discarded upon opening.
The information and data herein are believed to be accurate and have been compiled from sources believed to be reliable. It is offered for your consideration, investigation and verification.